On-Iine Detection of Instrument Transformer Measurement Error Based on BP NeuraI Network

Helong Li,Xiaolei Yuan,Xiaojian Zhao,Jinquan Zhao
DOI: https://doi.org/10.3969/j.issn.1000-3886.2019.06.024
2019-01-01
Abstract:Considering that the off-line detection method for the measurement error of the instrument transformer cannot truly reflect its actual operating conditions, an on-line detection method was proposed for the errors of the high-voltage measurement transformer.According to this method, a different frequency signal was applied to the secondary side of the transformer, and the transitive relationship between the primary and secondary sides of the transformer was established according to the different frequency voltage and current on the secondary side.The measurement error of the transformer was obtained by adopting the BP neural network algorithm.The proposed approach could reflect actual parameters of the transformer during on-line operation.It was a simple method, for what need to be done was just to make measurement on the secondary side of the transformer.Furthermore, it was a safe and accurate approach. Simulation results verified the accuracy of the proposed method and could provide a theoretical basis for on-line error detection for high-voltage voltage/current transformers.
What problem does this paper attempt to address?