Analysis of Reclaiming Residual Heat of the Flue Gas of Gas- Fired Boiler with a Condensing Air Heat Exchanger
GAO Dong-ming,SHI Xiao-jun
DOI: https://doi.org/10.3969/j.issn.1004-8774.2005.06.001
2005-01-01
Abstract:In this paper,for condensing air heat exchanger which reclaim latent heat of the exit flue gas of gas-fired boiler by air,Δt_x,which is the temperature difference of the flue gas and the air on the point where water vapor of the exit flue gas begin to condense in the heat exchanger,is used as variable, the variational relation of the last exist flue gas temperature,the quantity of air heated,heat recovered by air,the thermal efficiency of boiler and heat exchanger area is analyzed and calculated.It can provide the scientific basis for reclaiming the steam latent heat of gas-fired boiler with air.For a Shanbei natural-gas-fired boiler,when the air temperature is heated from 30℃ to 120℃ and the temperature difference Δt_x is reduced from 25℃ to 0℃,the calculational result show that the last exist flue gas temperature drop about 2℃,the heated air quantity is increased 1.5 times,the heat exchanger area rapidly increased to infinitude,here the high-point of thermal efficiency of boiler is increased by 4.67%,rovered latent heat is 28.6% of total amount of recovered heat.