Experimental Investigation on Heat Transfer Model for Secondary Side of Scaled C-shape Bundle Used in PRHR HX of AP1000

Yu-hao ZHANG,Dao-gang LU,Zhong-yi WANG,Guang-hao WU,Xiao-liang FU,Yan-hua YANG
DOI: https://doi.org/10.7538/yzk.2016.50.10.1763
2016-01-01
Abstract:T he separate‐effect overall scaled‐dow n passive residual heat removal heat ex‐changer (PRHR HX ) and in‐containment refueling water storage tank (IRWST ) experiment was conducted to investigate the secondary side heat transfer characteristics of the scaled C‐shape bundle used in PRHR HX in both the single‐phase natural convec‐tion stage and the two‐phase boiling heat transfer stage . The experimental data wereused to validate the traditional heat transfer correlations predicting the heat transfereffects of PRHR HX .The experimental results indicate that the thermal stratificationphenomenon is very obvious in the heat removal process . For the vertical bundle ofPRHR HX ,the traditional correlations tend to be conservative in both the single‐phaseand two‐phase heat transfer processes .In the aspect of the lower horizontal bundle ,theChurchill correlation is recommended in natural convection stage , and the Rohsenowpool boiling correlation is appropriate in the boiling heat transfer stage .However ,forthe upper horizontal bundle ,because of the additional influences of the buoyancy effectsand agitation of the fluid and bubbles ,the heat transfer effects are better than those ofthe lower horizontal bundle .
What problem does this paper attempt to address?