Calibration technology of microphone array

Yuan-shou LI,Bao CHEN,Xue ZHANG,Tao JIANG
DOI: https://doi.org/10.16652/j.issn.1004-373x.2014.24.019
2014-01-01
Abstract:Aerodynamic noise is usually broadband noise. The designed array needs to satisfy the measurement require?ments of both high and low frequency signals. The corresponding array form is designed when the frequency range of array mea?surement is determined. The noise source localization technology based on microphone array is the core test technique in the wind tunnel aerodynamic noise test technology. The accuracy of noise source localization depends mainly on the microphone ar?ray calibration technique. After the microphone phase array is installed,different frequency response and sensitivity,preamplifier, cable laying,power supply,frequency response of signal conditioner and the installation of microphone array can cause the phase difference and amplitude difference among all measurement channels in the data acquisition system. Correction of phase difference and amplitude difference of microphones can make all the microphone frequency responses consistent and ensure the accuracy of test result.
What problem does this paper attempt to address?