Frequency effect of metro and traffic induced ground vibrations response

Qiong ZHANG,Jun LEI,Yong-hong ZHAO,Yan-jun XIAO
DOI: https://doi.org/10.6038/pg20170655
2017-01-01
Abstract:Based on the ground vibration data around subway,we found that the ground vibration response was related to the frequency of source.However the observation was greatly influenced by ambient vibration environment.In order to explain the frequency effect of metro and traffic on ground vibration theoretically,a 2D finite element model was established to calculate the ground vibration,and 1 ~ 20 Hz excitation sources were respectively applied to the ground,underground,and both ground and underground.By comparison with the observed data,we got conclusions as follows:(1) As the coupling vibration of subway,traffic and strata,there existed a specific frequency which would lead the largest ground vibration;(2) Corresponding to the stratigraphic model in this paper,with the increase of the distance away from subway,the attenuation of ground vibration was slow when applied a source which frequency was below 5Hz.The attenuation was fast when large than 8 Hz;(3) The maximum response frequency on surface was different when excite at different locations.
What problem does this paper attempt to address?