Testing and analysis of vibration of ground surface by metro or underground vehicles

Zhang Jiedong,Xu Jun,Lei Jun,Yuan Mingwu,Liu Xida,Yu Chaomei,Zhang Zhensheng,Wang Ji
DOI: https://doi.org/10.3969/j.issn.1672-7916.2008.01.013
2008-01-01
Abstract:By testing and analysis of the vibration of ground surface for some special districts of Metro line 2 and 13 in Beijing,we have found that the vibration of which the frequency is higher than 10Hz is easy to be absorbed by the soil,but the vibration of which the frequency is between 1~10Hz is not easy.The vibration intensity in this frequency segment is about 30~100 times higher than that where is no Metro or underground vehicle passed.Moreover,the vibration in the segment of 1~10Hz can propagate horizontally as far as 100m with almost no damping.For the district where the track is isolated with a kind of equipments,such as Steel Spring Floating slab,the vibration intensity can be decreased effectively in a certain amount.However it is still 10 times higher than that where is no Metro or underground vehicle passed.Therefore,the operating Metro or underground vehicles will induce an intensive low frequency environment vibration which is severe for the normal operation of the precise laboratory instruments nearby.