Treatment of Cu-EDTA Containing Wastewater by Microwave-H2o2 Process

WANG Hongjie,CAO Zhe,ZHAO Zilong,DONG Wenyi
DOI: https://doi.org/10.11949/j.issn.0438-1157.20170776
2017-01-01
Abstract:In the present study, microwave-H2O2 (MW-H2O2) process was applied for the treatment of Cu-EDTA containing wastewater. The effects of reaction time, initial pH, H2O2 dosage, microwave power and coexistent substances were investigated in detail. The corresponding degradation mechanism of Cu-EDTA was also described. The results showed that for the elimination of 1.57 mmol·L-1 Cu-EDTA, the highest removal efficiencies of Cu (97.0%) and TOC (60.7%) were achieved under the optimum conditions (i.e. initial pH 3, H2O2 dosage 41 mmol·L-1, microwave power 210 W, and reaction time 10 min). In this situation, the effluent conductivity decreased to 1.8 mS·cm-1, and only 0.15 g·L-1 of the sludge yield was generated. The presence of coexistent substances such as NO-3 had nearly no effects on the degradation processes, while Cl-, H2PO-4 and tartaric acid were unfavorable to the oxidation degradation of Cu-EDTA. After treated for 4 min, Cu-EDTA was almost totally oxidized to various Cu-intermediates, which rapidly degraded within 4—6 min, leading to the final formation of low molecular organic acids, NH3-N, and inorganic carbon. The solid sludge mainly presented in the forms of CuO. Compared with traditional Fenton process, MW-H2O2 process exhibited more excellent performance in terms of oxidation efficiency, effluent conductivity and sludge yield.
What problem does this paper attempt to address?