CFD simulation of chemical conditioning unit of municipal sludge

Qi XU,Chao DENG,Yafei SHI,Xinyu XU,Wenbo YU,Chao LI,Ye CHEN,Sha LIANG,Jingping HU,Shu HE,Rong WANG,Changzhu YANG,Jiakuan YANG
DOI: https://doi.org/10.11949/j.issn.0438-1157.20150319
2015-01-01
Abstract:Chemical conditioning is commonly used before the mechanically dewatering process for sewage sludge. The flow field distribution of conditioning tank has a significant effect on conditioning when paddles are operating. Moving reference frame-volume of fluid model was used for simulating flow field distribution of a sludge conditioning tank with the inner diameter of 40 cm by CFD (computational fluid dynamics) technology, and the gas-liquid two-phase distribution was verified. The results showed that in the single straight blade paddle conditioning tank, the optimium ratio of paddle diameter to tank diameter was 1:1.75 and the optimum ratio of baffle width to tank diameter was 1:20. Under these optimum conditions, the fluid swirl could be effectively eliminated and the turbulent action could be enhanced. Furthermore, the flow field distribution simulation was conducted for pilot-scale conditioning tank with the inner diameter of 110 cm and the simulation results were compared with test results. Moving reference frame-volume of fluid model used in this study can provide references for design and optimization of similar sludge conditioning tank.