LTSA and combined index based MICA and PCA process monitoring and application

Wei JIANG,Xin WANG,Zhenlei WANG
DOI: https://doi.org/10.11949/j.issn.0438-1157.20151374
2015-01-01
Abstract:Independent component analysis (ICA) method is mainly used to monitor linear and non-Gaussian process, a method named modified independent analysis (MICA) is proposed to improve the non-Gaussian process monitoring performance. The method uses the information of process data to modify the monitoringprocess monitoring performance. The method uses the information of process data to modify the monitoring index of ICA. Many industrial process variables have characteristics of nonlinear, non-Gaussian and Gaussian mixture distribution. A method which based on LTSA algorithm and the combined index is proposed to solve these problems of the industrial process. Firstly, the local tangent space alignment (LTSA) algorithm is used to achieve the nonlinear dimensionality reduction of sample data. Then MICA and PCA methods are used to obtain non-Gaussian and Gaussian statistics, and the new statistic, which is weighted by these two statistics, is used for process monitoring. Finally, the proposed method has been applied to monitor the Tennessee-Eastman(TE) process and the ethylene cracking furnace to show its efficiency.
What problem does this paper attempt to address?