To Evaluate the Degradation of Heat Damaged Concrete Specimens after Curing Using Non-Linear Ultrasound Technique
,Kuang-Chih Pei,,Yu-Cheng Kan,,Yu-Ju Lin,,Jian-Jhou Lee
DOI: https://doi.org/10.58286/29890
2024-06-01
Abstract:In this research, Non-linear Ultrasound (NLU) technique was used to evaluate the degradation on heat damaged cement mortar specimen behaving explicit nonlinear. Mortars of Portland cement type I (or normal cement, NC) were chosen to mold the specimens with water cement ratios of 0.4, 0.5 and 0.6, and size of 5x5x5cm-cube and 5x5x2cm-brick. The specimens were grouped for heating at different temperatures (30, 200, 300, 400, 600, 800°C for 24 hours) to create degradations of different levels. After curing process in water for 28 days, mechanical property tests were carried out on each cube to get its stress-strain relation and strength. NLU tests were conducted on the brick specimens. The RITEC SNAP System with 250kHz/transmit and 500kHz/receive transducers was used to conduct the measurement of harmonics. The obtained amplitudes in spectrum of fundamental, 2nd and 3rd harmonics (A1, A2 and A3) and the amplitudes due to the background nonlinearity by facility (A01, A02 and A03) were analyzed to approach the nonlinear parameters for each specimen, such as the β and γ. The [(A01- A1),(A03/A 3 2 01 -A3/A13)] and[(A01-A1), |A02/A01 -A2/A12|] were applied as a nonlinear characteristic index to mark the quality of the microstructure of material, which could be related to the durability and workability of the material. The results showed a promised quantification method using NLU. Extended application can be expected.