Abstract:In order to improve the effluent quality,biochemical process was used in the upgrading of a pulp paper machine white water treatment plant.Combined with the commissioning of the biochemical system,the effect of temperature,HRT,volume load and other parameters on the pollutants removal was explored.Experimental results showed that the average removal rates of COD and SS at 20-25 ℃ were 15.79% and 16.96% higher than that at 15-20 ℃,reaching 81.66% and 61.96% respectively.After extending hydraulic retention time of aeration tank to 36 h,the effluent COD and SS were reduced to below 60 mg/L and 10 mg/L respectively.Effluent quality could reach the standard of recycling water in different processes such as pulping and paper making by adjusting the HRT of aerobic tank.