Discussion on Relationship between Pressures at Sink Traps and Horizontal Drainpipe

Zhe ZHANG,Jian-ming WU,Zhen-yi ZHAO,Bin GAO,Peng-hui YANG
DOI: https://doi.org/10.19853/j.zgjsps.1000-4602.2017.09.031
2017-01-01
Abstract:Building drainage system connects the indoor environment with outdoor drainage pipes.In the system,the inefficiency of sink traps and floor gully traps is one of the major causes of indoor environment pollution.In this study,the constant flow test method was used to explore the correlation between pressures measured at the sink trap and the horizontal drainpipe,and significant relationship was found.The average pressure and the maximum positive and negative pressures measured at sink traps could be used to estimate the corresponding pressures at the horizontal drainpipe.Based on the test resuits,preliminary causes were found for sewer smells,and could contribute to the further study of the "on-site detection technology for existing building drainage system".
What problem does this paper attempt to address?