Analysis of Slope Seepage under Siphon Drainage Based on Matlab Method

Shihua ZHANG,Hongyue SUN,Xiaoliang XIONG,Wenjun ZHANG
DOI: https://doi.org/10.3969/j.issn.1674-0610.2014.05.006
2014-01-01
Abstract:Infiltration of rainfall will cause the rise of groundwater levels in slope,which can re-duce the slope stability,thus reducing the groundwater level for increasing slope stability is extremely im-portant.Siphon drainage is a free power measures which can get rid of deep groundwater in slope,using matlab superior ability for solving the distribution of infiltration curve after siphon drainage what is helpful for seeking a reasonable and effective siphon drainage location,the research process for siphon drainage using approximate point sink to handle,relatively close to the actual project.Results of the study shows that the shallow drainage of the slope is suitable for emergency and deep drainage of the slope can effec-tively improve the long-term stability and defer the elevation of water table when next rainfall comes, which can provide a reference for the actual project.