Abstract:Backwashing wastewater from biological iron and manganese removal filter contains a lot of iron and manganese oxide-rich sludge,and direct emissions will produce negative impact on the environment.Researches on the removal capacity of As(Ⅴ) from drinking water were conducted using the iron and manganese oxide sludge gained from backwash wastewater.The results showed that:the adsorption conformed to the second-order kinetic model and the Langmuir isothermal adsorption model,with R2 more than 0.99,and the maximum adsorption capacity was 40.98 mg/g.The adsorption rate was more than 92% in acidic or neutral condition and it decreased with the increase of pH.H2PO4-and SiO32-had great effect on arsenic removal,while it was minor for HCO3-,SO42-,Mg2 + and Ca2 +.The adsorption enthalpy change △H0 was positive,which indicated the adsorption process was endothermic,meanwhile the minus Gibbs free energy change △G0 suggested the adsorption process was spontaneous.