Abstract:Under the condition of insufficient carbon source,denitrifying phosphorus removal bacteria can utilize nitrate as the electron acceptor to take up phosphorus by single carbon source.It is confirmed that denitrifying phosphorus removal bacteria exist in A2/O process.Therefore,the influence of the volume ratios of anoxic zone to aerobic zone on denitrifying phosphorus removal in the A2/O process for treating brewery wastewater was studied.The results show that when the volume ratios of anoxic zone to aerobic zone are 0.33,0.48 and 0.60,the resulting average total nitrogen removal efficiencies are 68.04%,79.64% and 85.70%,the average phosphorus removal efficiencies are 85.38%,90.80% and 96.84%,respectively.Also,the average COD removal efficiencies under the three ratios are all higher than 90%.Therefore,when the volume ratios of anoxic zone to aerobic zone continue to be increased,internal recirculation ratio shall be adjusted,otherwise the nitrate concentration will not be enough in anoxic zone and phosphorus will be released again.