Chemical-biological Flocculation/Suspended Carrier Bed Process for Low Strength Wastewater Treatment

张志斌,夏四清,赵建夫,饶应福
DOI: https://doi.org/10.3321/j.issn:1000-4602.2005.02.012
2005-01-01
Abstract:Chemical-biological flocculation / suspended carrier bed process was used for treatment of low strength municipal wastewater in order to find the optimum operating parameter. The result shows that in the treatment of municipal wastewater with COD 105-255 mg/L, TP 1.56-7.97 mg/L, SS 60-228 mg/L, NH_3-N 8.33-18.05 mg/L under the conditions of PAFC dosage 70 mg/L (9.7 mg/L based on Al_2O_3), PAM dosage 0.5 mg/L, sludge return ratio 33%, air/water ratio 2∶1, and DO 1.9-3.2, 1.3-2.5 and 0.3-1.5 in each channel, the removal rate of COD, TP, and SS is 75.8%, (76.2)%, and 90.6% respectively, and NH_3-N removal rate is more than 85%. The effluent COD, TP, SS, and NH_3-N concentration meets I-class criteria specified in Integrated Wastewater Discharge Standard.
What problem does this paper attempt to address?