Study on Advanced Treatment Process for Effluent of Chemical Biological Flocculation/Suspended Packed Bed

CHEN Yi-bo,XIA Si-qing,ZHANG Zhi-bin,YU Song
DOI: https://doi.org/10.3321/j.issn:1000-4602.2006.09.019
2006-01-01
Abstract:Chemical biological flocculation/suspended packed bed is a new and highly efficient process.The pilot-scale test shows that the average effluent TP,turbidity,NH_3-N and COD are 0.89 mg/L,9.7 NTU,8.8 mg/L and 37.3 mg/L,respectively.Flowing sand micro-flocculation filtration and chlorine dioxide synergetic disinfection were used as an advanced municipal wastewater treatment process.The results show that when the dosage of PAFC is 3.1 mg/L,the effluent TP,turbidity,(NH_3-N) and COD are 0.38 mg/L,2.2 NTU,7.2 mg/L and 26.6 mg/L,respectively;when the contact time of chlorine dioxide synergetic disinfection is more than 30 minutes and free residual chlorine is more than 0.5 mg/L,total coliform group is less than 3 CFU/L.This system is convenient in maintenance and steady in operation,the effluent quality is good and water quality index can meet the Miscellaneous Domestic Water Quality Standard (CJ/T 48-1999).
What problem does this paper attempt to address?