Experimental study on early temperature field of large thickness composite shear wall

Xiaoju WANG,Pengpeng CAI,Xuebin ZHANG,Wang LU,Yanfei MA,Biao LI
DOI: https://doi.org/10.3969/j.issn.1008-1933.2018.02.011
2018-01-01
Abstract:Large thickness steel-concrete composite shear walls will produce lots of hydration heat during the process of construction and it's hard to dissipate.The temperature problem can easily trigger crevices in the wall.In order to study the inchoate law of temperature variation of the large thickness steel-concrete composite shear walls,full size wall simulation test was carried out with 1.7 m in thickness.We conducted a real-time temperature monitoring,lasting 30 days,since concreting.Through the analysis of temperature variation,change of temperature difference and temperature gradient,we studied the inner connection between temperature field and crevices in walls.Contrasting with the specification,we offered a proposal over the prevention of temperature crevices of steel-concrete composite shear walls.
What problem does this paper attempt to address?