Study on Residential PM2.5 Pollution Status Quo and the Relationship between Indoor and Outdoor

Yu ZHAO,Hong-wei TAN
DOI: https://doi.org/10.3969/j.issn.1003-0344.2019.01.006
2019-01-01
Abstract:Taking the 13 households in Shanghai as the object, the on-line continuous monitoring of various parameters was conducted to have a better knowledge of status of indoor air quality. Specifically, this one-year continuous monitoring aims at parameters of indoor temperature, indoor humidity, CO2 concentration, particulate matter (PM2.5) concentration, and some human behavior related parameters, such as the window switch status in Shanghai. Based on these collected datasets, it can be calculated that the indoor CO2 concentration was the highest in winter, and the median level did not exceed the national standard of 1000 ppm. Compared with mechanical ventilation, natural ventilation houses have insufficient ventilation. However, at the same time, opening the window can increase the air exchange rates and significantly reduce indoor CO2 levels. Furthermore, the indoor temperature and humidity in the transitional season all meet the comfort requirements, and the excellent rate of indoor PM2.5 concentration reached 93.4%. Consequently, when outdoor pollution occurs in Shanghai in winter, it is suggested to adopt short-term ventilation mode with window opening and purifier assisted ventilation, while natural ventilation mode should be adopted to ensure the thermal comfort of the occupants at other times, and the length of night window opening should be increased.
What problem does this paper attempt to address?