Denitrification Research on the Treatment of Taii-Water from Industry Ciuster District Using Verticai Fiow Constructed Wetiand

Tao Chen,Xiang Wang,Zhaojun Zhu,Defang Kong,Luji Yu
DOI: https://doi.org/10.11894/iwt.2018-0888
2019-01-01
Abstract:The vertical flow constructed wetland was adopted for the tail-water treatment in the sewage plant in the industry cluster district. A mixed matrix of limestone,sulfur,and pyrite were laid in the wetland bed. The processing capacity of the wetland system could reach up to 40 000 m3/d,and the HRT was determined as 24 hours. The effect of wetland system on the removal ratio of the pollutant was measured during the stable operation. The results showed that COD and TN removal ratios in the wetland system could reach up to 18.93% and 56.83%,respectively. The concen-trations of TN,NO3--N,NH3-N,NO2--N in the effluent were 7.60-13.99,4.17-7.29,0.81-2.17 and 1.01-4.07 mg/L, respectively. Thus,the average effluent quality of the system met Grade A of Standard of Pollutant Discharge Standard of Urban Sewage Treatment Plant(GB 18918—2002).
What problem does this paper attempt to address?