Experimental Investigation of Cooling Performance of Air-Cooled Turbine Blade in a High-Temperature Wind Tunnel

Chao MA,Ming-hai HUANG,Bing GE,Yong-bin JI,Shu-sheng ZANG
DOI: https://doi.org/10.13675/j.cnki.tjjs.2016.03.012
2016-01-01
Abstract:In order to investigate the cooling performance of a turbine blade scoured by high-temperature gas flow,an annular cascade test rig was set up. The distribution of temperature on suction side of blade was mea-sured by an infrared camera. Effects of mass flow ratio (0.016~0.036) and temperature ratio (0.47~0.58) on cooling performance of blade were studied. Results showed that due to the influence of different cooling perfor-mance owned by the front and rear cooling chambers, the front and rear parts of the suction side of blade show different cooling performance. In the experiment, the area-averaged cooling efficiencies of the front and rear parts of suction side of blade increase by 30.4%and 49.1%with mass flow ratio increasing from 0.016 to 0.036, respectively. In the same process, the relative temeprature of the two parts decreases by 0.017 and 0.049, re-spectively. In case of the temperature ratio increasing from 0.47 to 0.58 with the mass flow ratio unchanged,the cooling efficiencies of the front and rear parts of suction side of blade both have minor changes,they decrease by 2.9% and 9.6%, respectively. However, the relative temperature of the two parts increases by 0.013 and 0.015,respectively, in the same process.