Development of Low Temperature Experiment Device for Bridge Specimen

CHEN Huan-xin,LIU Wei-wei,LI Hong-min,WU Zhi-hui
DOI: https://doi.org/10.3321/j.issn:1001-4632.2005.04.008
2005-01-01
Abstract:According to the low temperature environment needed for bridge specimen experiments, a low (temperature) experiment device for bridge specimen was developed to carry through live load (or) dead load (experiments,) in which -50 low temperature was obtained. The device adopted a R22 double-stage compression and refrigeration system. Low temperature box could bear large loads during the experiments. The key problems, such as reducing cold leakage, regulating refrigerant mass flux and protecting refrigeration system, were solved. Load experiments on 40 bridge specimens of composite beam were carried out under -50, -30, -15 and 0 in low temperature experiment device. After 3 months operation, the working results (indicate) that the experiment device is of high reliability and with good refrigeration effects. It can meet the low temperature requirements for bridge specimen.