A Research on the NO X Reduction Effects of SCR Systems in City Buses

Jiadong Guo,Yunshan Ge,Lijun Hao,Jianwei Tan,Zihang Peng,Chuanzhen Zhang
DOI: https://doi.org/10.3969/j.issn.1000-680X.2015.11.001
2015-01-01
Abstract:NOX emissions from three buses with SCR systems are measured by using portable emission measurement system in real-world conditions, the NOX emission factors in both conditions ( with and without urea in-jection) are compared and their NOX reduction rates of SCR systems are calculated. The results show that the State-IV diesel bus has the lowest NOx reduction rate of SCR system due to its low exhaust temperature and less volume of catalyst, whose effects gradually become apparent only when vehicle speed is higher than 30km/h, with an average NOX reduction rate of only 10 %;the State-V CNG bus has the highest NOX reduction rate due to its high exhaust temperature even at low speed and higher proportion of NO2 in NOX emission, and its NOX reduction rate basically does not change with vehicle speed, resulting in an average NOX reduction rate of 85%; while the NOX reduction rate of State-V diesel bus is in-between with an average NOX reduction rate of around 70%. As for the emission of NOX+ HC, the lowest is the State-V diesel bus, the highest is the State-IV diesel bus, while the NOX+HC emission of State-V CNG bus, due to its high emission of methane, is close to but slightly lower than that of State-IV diesel bus.
What problem does this paper attempt to address?