Stopping Power of Heavy Ions in Human Body Tissue

Zhi-yong WEI,Li-hui ZANG,Ming LI,Wo FAN,Bin KANG,Mei-hua FANG
DOI: https://doi.org/10.3969/j.issn.1005-2615.2005.05.004
2005-01-01
Abstract:In charged particle conformal radiotherapy,the energy deposition in the tumour area of the heavy ion beam is controlled by the energy range,energy straggling and the Bragg peak.A parameterized formula is developed to calculate stopping power values for heavy ions,such as~(12)C in human tissue and tissue equivalent materials with the uncertainty about 3%. The ranges and stopping powers for~(12)C in bone,fat,muscle,water and tissue equivalent materials,polyethylene,lucite and polystyrene,are calculated.The energy-range relation in the muscle for ~(12)C is obtained.The energy straggling and angular straggling for ~(12)C in the muscle increase when the energy loss increases.The conformity of the energy deposition in the cancer therapy is discussed.
What problem does this paper attempt to address?