Calculations of the cell survival rate after irradiating with minibeams of protons and $^{12}$C

A.O. Svetlichnyi,S.D. Savenkov,I.A. Pshenichnov
2024-11-22
Abstract:The propagation of minibeams of protons and $^{12}$C in a water phantom was modelled with Geant4 v10.3, and the survival probabilities of human salivary gland cells representing healthy and tumour tissues of normal radiosensitivity were calculated with the modified microdosimetric kinetic model. The advantage of minibeams over homogeneous irradiation in sparing healthy tissues proximal to the tumour was demonstrated. Survival-volume histograms were proposed to quantify the difference in the survival probability of cells inside and outside the minibeam spots.
Medical Physics
What problem does this paper attempt to address?
The problem that this paper aims to solve is to evaluate the effects of proton and carbon - ion minibeams in radiotherapy, especially their advantages over uniform irradiation in protecting healthy tissues adjacent to tumors. Specifically, the research attempts to answer the following key questions through simulation and calculation: 1. **Propagation of Proton and Carbon - Ion Minibeams in Water Phantoms**: Use the Geant4 toolkit to simulate the propagation paths and dose distributions of proton and \(^{12}\text{C}\) (carbon - 12) minibeams in water phantoms. 2. **Calculation of Cell Survival Rates**: Based on the modified micro - dosimetric kinetic model (MKM), calculate the survival probabilities of human salivary gland cells (HSG cells) after being irradiated by proton and carbon - ion minibeams. These cells represent healthy tissues and tumor tissues with normal radiosensitivity. 3. **Comparison between Minibeams and Uniform Irradiation**: By comparing the cell survival rates under minibeam irradiation and uniform irradiation, evaluate the ability of minibeams to reduce damage to healthy tissues. 4. **Proposal of Survival Volume Histograms (SVHs)**: In order to quantify the effect of minibeam irradiation on cell survival rates, survival volume histograms are proposed to describe the volume proportions with specific survival rates in the entrance area and the target area. ### Main Conclusions The research shows that at the entrance of the water phantom, the average cell survival rates under proton and carbon - ion minibeam irradiation are significantly higher than those under uniform irradiation, indicating that minibeams have obvious advantages in protecting healthy tissues adjacent to tumors. In addition, the differentially calculated survival volume histograms (differential SVHs) further quantify the differences in cell survival rates inside and outside minibeam irradiation. ### Formula Summaries 1. **Saturation - corrected Dose - Mean Lineal Energy \( y^* \)**: \[ y^*=\frac{\int_{0}^{\infty}(1 - \exp(-y^{2}/y_{0}^{2}))f(y)\,dy}{\int_{0}^{\infty}yf(y)\,dy} \] where \( y_{0} = 150 \, \text{keV/}\mu\text{m} \) and \( f(y) \) is the probability density function of lineal energy \( y \). 2. **Parameter \( \alpha \) in the Linear - Quadratic Model (LQM)**: \[ \alpha=\alpha_{0}+\beta\frac{\pi r_{d}^{2}}{\rho}\frac{dy^*}{dz} \] where \( \alpha_{0} = 0.13 \, \text{Gy}^{-1} \), \( \beta = 0.05 \, \text{Gy}^{-2} \), \( \rho = 1 \, \text{g/cm}^3 \), \( r_{d} = 0.42 \, \mu\text{m} \). Through these studies, the paper provides important theoretical bases and technical supports for proton and carbon - ion minibeam therapies, which is helpful for optimizing future radiotherapy methods.