Clinical Application of Electrocardiogram-Triggered High-Pitch Dual-Source Coronary CT Angiography at 80kv Low Radiation Dose Integrated Iterative Reconstruction Technology
Han Yang,Han Ruijuan,Chen Guoqiang,Zhao Ruiping,Sun Kai
DOI: https://doi.org/10.3877/cma.j.issn.2095-655x.2017.01.001
2017-01-01
Abstract:Objective To assess the impact of image quality and radiation dose levels of low tube potential with electrocardiogram (ECG)-triggered high-pitch coronary computed tomography angiography (CCTA) of 2nd generation dual-source computed tomography.Methods One hundred and twenty patients with suspected coronary arteries underwent high-pitch prospectively ECG-triggering CCTA.All subjects had registered for this research and hospitalized.Prospective study was conducted with dual-source coronary computed tomography using iodine contrast agents.All patients signed informed consent of the Ethical Committee of Baotou Central Hospital and the ethics committees approved the consent procedure.Sixty patients were examined with high-pitch mode by a 2nd-generation dual-source CT system at 80kV and SAFIRE iterative reconstruction (80kV+SAFIRE) or with 80 or 100kV and FBP reconstruction (80kV+FBP,100kV+FBP) respectively.Subjective image quality was evaluated double-blindly by two experienced radiologists.Objective image quality was measured by means of various regions of interest.Results The noise values of aortic root,right coronary artery(RCA),left coronary artery(LAM) in 80kV+SAFIRE group (23.62±5.57,18.89±8.80,17.42±5.94) were lower than those of 80kV+FBP group(31.66±8.41,24.15±15.84,22.45±5.62) as well as 100kV+FBP group(27.38±8.01,22.76±4.41,22.09±4.51),the differences were significant (F=19.09,4.36,22.15;P<0.05).The signal to noise ratios (SNR) of aortic root,RCA,LAM in 80kV+SAFIRE group (24.89±8.37,32.33±12.80,34.46±11.73) were higher than those of 80kV+FBP group (18.84±6.43,24.89±9.08,25.70±7.90) and 100kV+FBP group (19.66±4.43,24.12±7.35,24.93±7.86) ,the differences were also significant (F=21.08,16.69,26.55;P<0.01).The effective dose (ED) of 80kV+SAFIRE ,80kV+FBP groups decreased significantly compared with 100kV+FBP group (F=38.14;P<0.01).The ED of three group were (0.47±0.03)mSv,(0.47±0.05)mSv,(1.00±0.04)mSv respectively.Conclusion sHigh-pitch prospectively ECG-triggered CCTA at 80kV enables to obtain diagnostic image quality with 2nd-generation CT using iterative reconstruction technique in patients.This methodology can reduce radiation dose levels obviously compared with the 100kV group.The radiation dose of the 80kV group is reduced by 53%.