Longitudinal Guided Waves in Liquid-Filled Pipes for Viscosity Measurement

Jinyu Ma,Meirong Zhao,Xinjing Huang
DOI: https://doi.org/10.11784/tdxbz201608003
2017-01-01
Abstract:The feasibility of utilizing longitudinal (L)guided waves in liquid-filled pipes to measure viscosity is demonstrated by deploying COMSOL software and experiments.The real wavenumbers,complex frequencies and wave structures of guided waves and the displacement and acoustic pressure distributions of various modes are calculated by configuring the finite element simulations as acoustic-solid interaction module and eigenvalue solver.The real wavenumbers and the real parts of the complex frequencies constitute the group velocity dispersion curves (GVDCs),and the imaginary and real parts of the complex frequencies constitute the attenuation dispersion curves (ADCs).GVDCs and ADCs with different liquid properties are calculated and tested.The liquid viscosity has no effect on the GVDCs while the ADCs go higher as the viscosity increases.Both the ADCs in the dispersion region and GVDCs go lower while the ADCs in the plateau region remain constant as the liquid density increases.Both the GVDCs and ADCs stretch and shift rightwards as the compressional wave velocity increases.
What problem does this paper attempt to address?