Diagnostic Accuracy of Quantitative Flow Ratio for Assessment of Coronary Stenosis Significance from a Single Angiographic View: A Novel Method Based on Bifurcation Fractal Law

Shengxian Tu,Daixin Ding,Yunxiao Chang,Chunming Li,William Wijns,Bo Xu
DOI: https://doi.org/10.1002/ccd.29592
IF: 24
2021-01-01
Journal of the American College of Cardiology
Abstract:Objectives We aimed to evaluate the diagnostic accuracy of computation of fractional flow reserve (FFR) from a single angiographic view in patients with intermediate coronary stenosis. Background Computation of quantitative flow ratio (QFR) from a single angiographic view might increase the feasibility of routine use of computational FFR. In addition, current QFR solutions assume a linear tapering of the reference vessel size, which might decrease the diagnostic accuracy in the presence of the physiologically significant bifurcation lesions. Methods An artificial intelligence algorithm was proposed for automatic delineation of lumen contours of major epicardial coronary arteries including their side branches. A step-down reference diameter function was reconstructed based on the Murray bifurcation fractal law and used for QFR computation. Validation of this Murray law-based QFR (mu QFR) was performed on the FAVOR II China study population. The mu QFR was computed separately in two angiographic projections, starting with the one with optimal angiographic image quality. Hemodynamically significant coronary stenosis was defined by pressure wire-derived FFR <= 0.80. Results The mu QFR was successfully computed in all 330 vessels of 306 patients. There was excellent correlation (r = 0.90, p < .001) and agreement (mean difference = 0.00 +/- 0.05, p = .378) between mu QFR and FFR. The vessel-level diagnostic accuracy for mu QFR to identify hemodynamically significant stenosis was 93.0% (95% CI: 90.3 to 95.8%), with sensitivity, specificity, positive predictive value, negative predictive value, positive likelihood ratio, and negative likelihood ratio of 87.5% (95% CI: 80.2 to 92.8%), 96.2% (95% CI: 92.6 to 98.3%), 92.9% (95% CI: 86.5 to 96.9%), 93.1% (95% CI: 88.9 to 96.1%), 23.0 (95% CI: 11.6 to 45.5), 0.13 (95% CI: 0.08 to 0.20), respectively. Use of suboptimal angiographic image view slightly decreased the diagnostic accuracy of mu QFR (AUC = 0.97 versus 0.92, difference = 0.05, p < .001). Intra- and inter-observer variability for mu QFR computation was 0.00 +/- 0.03, and 0.00 +/- 0.03, respectively. Average analysis time for mu QFR was 67 +/- 22 s. Conclusions Computation of mu QFR from a single angiographic view has high feasibility and excellent diagnostic accuracy in identifying hemodynamically significant coronary stenosis. The short analysis time and good reproducibility of mu QFR bear potential of wider adoption of physiological assessment in the catheterization laboratory.
What problem does this paper attempt to address?