Investigation of the Effect of a Resistance Grid on a Tunnel Ventilation Physical Distorted Model

Yunxiao Xin,Yaqiong Wang,Xiaozhao Li,Kai Lai,Yongli Xie
DOI: https://doi.org/10.1016/j.tust.2020.103794
IF: 6.9
2021-01-01
Tunnelling and Underground Space Technology
Abstract:According to the equivalent design theory, the length of a tunnel model can be shortened by applying a resistance grid in a tunnel ventilation model experiment. To study the effect of a resistance grid on the ventilation model, this paper analyses the influence of the distance, number, and type of resistance grids in ventilation experiments via a series of model experiments and takes the Dabieshan Tunnel as a case study for verification. The results show that the influence range of the resistance grid decreases with an increasing number of grid holes. When the number of holes per unit area of the grid is greater than 500, the influence length is less than three times the equivalent model diameter. The critical velocity of the model is almost unaffected by the grid spacing, grid number, or grid type. For the same model material, the resistance factor of the model decreases with increasing model size, and the local resistance factor of the grid in the model also proportionally decreases. When the aperture ratio is similar, the local resistance factor of a multiorifice plate grid is greater than that of a wire mesh grid, and the local resistance factor of a square hole grid is greater than that of a circular hole grid. With increasing aperture ratio, the decrease rate of the local resistance factor of a wire mesh grid is less than that of a multiorifice plate grid. The local resistance factor in each grid decreases with an increasing number of grid groups.
What problem does this paper attempt to address?