Effect of Blockage-Fire Distance on Buoyancy Driven Back-Layering Length and Critical Velocity in a Tunnel: an Experimental Investigation and Global Correlations

W. Tang,L. H. Hu,L. F. Chen
DOI: https://doi.org/10.1016/j.applthermaleng.2013.06.033
IF: 6.4
2013-01-01
Applied Thermal Engineering
Abstract:Experiments are conducted in a model tunnel to study the effect of a vehicular blockage at the upstream of the fire source on the buoyancy driven back-layering length and critical velocity in a longitudinal ventilated tunnel. The relative distance between the vehicular blockage and fire source are ranged in 1 m similar to 6 m. It is found that with no blockage, experimental data on back-layering length and critical velocity can be well collapsed by Wu model and Li model, respectively. However, with the increase in blockage-fire distance, both the back-layering length and critical velocity first decrease then approach to constants similar to those with no blockage. The modified Wu model and Li model amended by cross-sectional blockage ratio proposed by Lee, which does not include the factor of blockage-fire distance, still fail to predict experimental results for different blockage-fire distances. Thus a dimensionless modification coefficient eta is proposed and correlated non-dimensionally with the normalized blockagefire distance to account for this effect. Finally, global models are proposed to predict back-layering length and critical velocity including factors of both cross-sectional blockage ratio and blockage-fire distance, which are shown to well collapse the experimental measurements in good agreement. (C) 2013 Elsevier Ltd. All rights reserved.
What problem does this paper attempt to address?