Numerical Simulation of SGEMP Generated by X-Rays From High-Altitude Nuclear Detonations
Hantian Zhang,Qianhong Zhou,Haijing Zhou,Qiang Sun,Mengmeng Song
DOI: https://doi.org/10.1109/tns.2023.3249288
IF: 1.703
2023-04-21
IEEE Transactions on Nuclear Science
Abstract:In this work, the system generated electromagnetic pulse (SGEMP) generated by the X-rays from high-altitude nuclear detonation (HAND) is investigated by numerical simulation. First, based on the mass attenuation coefficients, the spatial distributions of energy fluence, spectrum, and energy deposition of the X-rays propagating in air are calculated, as well as the number density of preionized air. Then, the photon–electron transport between the attenuated X-rays and the metal surface is simulated using the Monte Carlo method. Finally, the SGEMP of a metal cylinder is calculated based on the particle-in-cell (PIC) method. The results show that the electric field close to the irradiated surface consists of a short positive pulse with high intensity and a long negative pulse with low intensity. The magnitude of the electromagnetic field increases upon increasing yield of burst, while decreases upon increasing explosion height and distance from the burst point.
engineering, electrical & electronic,nuclear science & technology