Evaluations on the safety design standards for dams with extra height or cascade impacts. Part I:fundamentals and criteria

李斌,周兴波,陈祖煜,周建平,王浩
DOI: https://doi.org/10.13243/j.cnki.slxb.20150249
2015-01-01
Abstract:The rapid development of China’s hydropower projects has resulted in a number of large dams whose heights exceed 200 m, an applicability limit of various design codes. Another concern comes from the cascade hydropower devolvement on a river, in which break of one dam may cause serious downstream secondary disasterds. Based on a comprehensive review on the social and professional safety control stan?dards the authors propose in these paper two extra classes as well as their related design criteria to the ex?isting Chinese dam classification systems. Class E2 refers to a dam with a height ranged between 200-250 m, or a dam whose breaching would cause a secondary break of a downstream Class 1 dam if early warn?ing is not available. The allowableannual probability of failure, reliability index and slope safety factor are specified as 5 × 10-8, 4.45, and 1.6 respectively. Class E2 refers to a dam with a height ranged between 250-300 m, or a dam whose breaching would cause a secondary break of a downstream Class 1 dam even with early warning. The allowable annual probability of failure, reliability index and slope safety factor are specified as 10-8, 4.7, and 1.7 respectively. An in-depth study on risks and standards associated with these dams has been provided to assess the applicability of the proposed criteria which can be useful for the work of code revision.
What problem does this paper attempt to address?