Study on the Characteristics of 2, 4-Dichlorophenol in Water Degraded by UV/PS

CHEN Ju-xiang,GAO Nai-yun,YANG Jing,WANG Chao-hui,GU Zhen-chuan,Jiang Chuang
DOI: https://doi.org/10.3969/j.issn.1000-6923.2017.06.020
2017-01-01
Abstract:The study compared the removal effects and the first order reaction kinetics constants of 2, 4-DCP with PS、UV and UV/PS processes, respectively. Investigated the contribution rate of OH? and SO4?-in the photolysis reaction, calculated the two order kinetics constants for SO4?- with 2, 4-DCP reactions. Meanwhile, the degradation rates in actual water conditions were tested and the economic budge of UV and UV/PS processes were calculated and compared. The results showed that the removal rate of 2, 4-DCP was only 4% in the PS process alone, 46.2% in UV process. The degradation percentage can reach as high as 96.4% with UV/PS process, which effectively improved the degradation effect of 2, 4-DCP, meanwhile 2, 4-DCP degradation by PS, UV and UV/PS fitted the pseudo-first-order reaction equation and the kobs (reaction rate constant) was 0.4×10-3, 6.2×10-3 and 35.1×10-3min-1, respectly. The main contribution function of the photolysis reaction was SO4?-, the second-order-reaction constants for SO4?- with 2, 4-DCP was 7.07×109(mol/L)-1s-1. The photo-degradation rates of 2, 4-DCP in three actual water conditions (Xidong water works, Xijiu reservoir, Hengshan reservoir) were higher than in the ultrapure water. The energy utilization rate of UV/PS cooperative system is the highest during economic calculation.
What problem does this paper attempt to address?