R/Q Measurements of Multi-Gap Metamaterial Extended Interaction Resonant Cavity Using Perturbation Method
Ning Li,Xuanming Zhang,Shaozhe Wang,Jianjun Zou,Junjie Huang,Shifeng Li,Yongming Li,Yurong Liu,Huarong Gong,Yubin Gong,Zhaoyun Duan
DOI: https://doi.org/10.1109/IVEC56627.2023.10157819
2023-01-01
Abstract:In this paper, the
<tex xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">$\boldsymbol{R/Q}$</tex>
measurement method of a metamaterial extended interaction resonant cavity (MEIRC) is investigated using the perturbation method. The
<tex xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">$\boldsymbol{R/Q}$</tex>
expression for MEIRC is accordingly given, which depends on the natural frequency
<tex xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">$\boldsymbol{f_{0}}$</tex>
of the MEIRC, the perturbation frequency shift
<tex xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">$\Delta f$</tex>
, and the structural parameters. The
<tex xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">$\boldsymbol{R/Q}$</tex>
expression is verified by CST simulation where a PTFE dielectric cylinder is considered as the perturbed body. After fabrication and assembly of the MEIRC, the measured natural frequency
<tex xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">$\boldsymbol{f_{0}}$</tex>
of the double-gap MEIRC is 2.427 GHz, with an
<tex xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">$\boldsymbol{R/Q}$</tex>
of 182.5
<tex xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">$\Omega$</tex>
and an
<tex xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">$\boldsymbol{R/Q}$</tex>
error of 1.5% relative to the simulated one. In addition, the measured natural frequency
<tex xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">$\boldsymbol{f_{0}}$</tex>
of the three-gap MEIRC is 2.443 GHz,
<tex xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">$\boldsymbol{R/Q}$</tex>
is 286.0
<tex xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">$\boldsymbol{\Omega}$</tex>
, and the
<tex xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">$\boldsymbol{R/Q}$</tex>
error is 5.7% relative to the simulated one. The measurements reported here pave the path for developing the metamaterial extended interaction devices.