A Rapid Coordinate Transformation Method for Serial Robot Calibration System

QIAO Guifang,SUN Dalin,SONG Guangming,WEN Xiulan,WEI Zhong,SONG Aiguo
DOI: https://doi.org/10.3901/jme.2020.14.001
2020-01-01
Journal of Mechanical Engineering
Abstract:: To solve the problem of coordinate transformation between the industrial robot base coordinate {B} and the laser tracker measurement coordinate {T} in the serial robot calibration system, a rapid coordinate transformation method combining multi-point fitting method and screw axis measurement method is proposed. Firstly, the rotation matrix R is obtained by screw axis measurement method, and the displacement vector T is obtained by multi-point fitting method. The transformation matrix TB R is calculated based on the rotation matrix R and the displacement vector T . The experimental results show that the measurement time of this method is 184.68 s less than that of the multi-point fitting method. The comprehensive (Root mean squared error, RMSE) is increased by 0.215 mm. Compared with the joint circle intersection based method, the comprehensive RMSE of this method is reduced by 0.626 mm. However, the measurement time is just increased by 51.26 s. Compared with the base plane fitting method, the comprehensive RMSE and the measurement time of this method are reduced by 2.790 mm and 120.0 s, respectively. Therefore, the accuracy of the proposed rapid coordinate transformation method is much better than that of the screw axis measurement method. Compared with the multi-point fitting method, the proposed method has similar accuracy and better measurement efficiency.
What problem does this paper attempt to address?