Study on Effect of Cable Vibration on Dynamic Behavior of Cable-Stayed Bridges

Hua Zang,Yongming Tu
2010-01-01
Abstract:To super-long span cable-stayed bridges, carbon fiber-reinforced polymer (CFRP) cables are the good substitution for steel cables because of the advantages including high specific strength-to-weight and stiffness-to-weight ratios, excellent corrosion resistance, as well as outstanding fatigue behavior, which can solve the problems existing in steel cables such as low carrying efficiency and corrosion. The density of CFRP is only 20% of that of steel, therefore the dynamic performance of cable-stayed bridges with steel cables and CFRP cables will be different especially for super-long span bridges. As a case study, three-dimensional FEM analyses using the ANSYS program were carried out for the two types of cables based on the Sutong Yangtze River. The mode analyses were made considering cable vibration. The results show that the former 10 orders frequencies of the CFRP cable-stayed bridge do not change for its high natural vibration frequencies and only former 3 orders frequencies of the steel cable-stayed bridge do not change. In addition, the results indicate that a CFRP cable can be simulated by single-pole element because vibration energy dissipation of CFRP cables is relatively small for its light weight.
What problem does this paper attempt to address?