EXPERIMENTAL STUDY OF ENVIRONMENTAL VIBRATION INDUCED BY VIADUCT RAIL TRANSIT

J. G. Chen,H. Xia,J. B. Yao
2009-01-01
Abstract:To investigate the environmental vibration caused by viaduct rail transit, a field test for measuring the ground vibration caused by trains running on Beijing Metro Line 5 was carried out. The acceleration data from the test was analyzed in the time domain and the frequency domain. The conclusions are as follows: the vertical vibration levels of the ground are 55-91 dB when the train runs on the common track while 60-83dB on the ladder track; The ground vertical vibration level decreases with the distance to the viaduct, while at the distance of 15 meters, there occurs an obvious rebound, and the bigger the vibration level, the more obvious the rebound; The ground vibration when the train runs on the ladder track is smaller at the near ground position but bigger at the distant position compared with those when the train runs on the common slab track; When the vibration propagates in soil, the rate of decay of high frequency component is larger than that of low frequency component, therefore, the vibration of distant points is mainly caused by low frequency vibration.
What problem does this paper attempt to address?