Passivity-Based Design of Resonant Current Controllers Without Involving Partial Derivative
Chao Gao,Shan He,Pooya Davari,Ka Nang Leung,Poh Chiang Loh,Frede Blaabjerg
DOI: https://doi.org/10.1109/tpel.2023.3313178
IF: 5.967
2023-01-01
IEEE Transactions on Power Electronics
Abstract:In terms of digital control delay, dissipation of the current controller is necessary to enhance the interactive stability between grid-following converters and the grid. The key principle is to make the real part of the converter output admittance non-negative below Nyquist frequency. Besides the fundamental current control, a phase-lead compensation should be introduced for the dissipative design of harmonic resonant controllers. However, derivation of the compensation angle requires calculating the partial derivative of real-part of converter output admittance, which is non-trivial, especially in the presence of grid voltage feedforward. This letter provides a simple calculation method for the compensation angle to achieve dissipativity, and its effectiveness is verified through experiments.
engineering, electrical & electronic