Microfluidized Bed Thermogravimetry Combined with Mass Spectrometry (MFB-TG-MS) for Redox Kinetic Study of Oxygen Carrier

Ye Li,Zhenshan Li,Ningsheng Cai
DOI: https://doi.org/10.1021/acs.energyfuels.0c00924
IF: 4.6541
2020-01-01
Energy & Fuels
Abstract:Heterogeneous reduction/oxidation reactions in fluidization state play vital roles in chemical looping combustion (CLC) processes. A key task in studying heterogeneous reduction/oxidation reactions and developing CLC technology is to measure the heterogeneous redox kinetics of oxygen carrier particles in fluidizing state. Here we compared two methods to measure heterogeneous redox kinetics of fluidizing oxygen carrier particles by both the solid mass signal measured from the weight balance and the gas evolution signal measured by mass spectroscopy. Microfluidized bed thermogravimetry combined with the mass spectrometry method (MFB-TG-MS) was used here to measure the tail gas signal, and heterogeneous redox kinetics was obtained from the analysis of the tail gas signal. The oxidation by air and reduction by H-2 of a manganese oxide were chosen to be the target reactions. The heterogeneous redox kinetics of manganese oxide obtained from the analysis of the tail gas signal measured by mass spectroscopy was compared with the previously developed MFB-TGA method in which the real-time solid mass signal of fluidizing oxygen carrier was measured by weight balance. A K-L two-phase fluidized bed model, developed by Kunni and Levenspiel to describe the mass transfer and reaction behavior in a bubbling fluidized bed, was used to analyze the experimental data from MFB-TG-MS. It was found that there is no big difference for the reduction kinetics of manganese oxide measured by the two signals. Mass balance was achieved for the gas signal method, and the outlet mole fraction of H-2 is consistent with the model result, while for the fast heterogeneous oxidation reaction, the deconvolution of the gas signal is needed. It was found that the oxidation conversion calculated by the deconvoluted gas signal was close to the previous results measured by the weight balance method, while the estimation of the initial oxidation rate from the gas signal was not so accurate. For studying many redox cycles of oxygen carrier, it is more suitable to obtain the heterogeneous kinetics from the solid mass signal measured by the weight balance method. We anticipate that this new MFB-TG-MS method can be readily applied to measure fast heterogeneous redox kinetics of fluidizing oxygen carrier and provide a more comprehensive understanding for heterogeneous reactions occurring inside the fluidized bed reactor.
What problem does this paper attempt to address?