Frictional Pressure Drop of Two-phase Flow in Rifled Water Wall Tubes
Wei-shu WANG,Jian-lan HU,Wei-hui XU,Hong-fang GU,Yu-shan LUO,Ting-kuan CHEN,Xiao-jin ZHU
DOI: https://doi.org/10.3321/j.issn:1000-6761.2007.05.022
2007-01-01
Abstract:The frictional pressure drop characteristics of single phase and also of two phase flow in φ28.6×5.8(mm) 4-threaded rifled water wall tubes,under adiabatic as well as heated conditions,were experimentally investigated in the following working ranges:pressure 9 to 35 MPa,mass flow 600 to 1800 kg/m~2·s,dryness 0 to 1.Results indicate that the frictional pressure drop characteristics of rifled tubes,under adiabatic and under heated conditions,are not the same.The single phase flow friction coefficient f of heated tubes is lower than that of insulated tubes,while the two phase flow friction scale factor multiplication factor φ~2_(10) is higher than that of insulated tubes.Whether under heated or insulated conditions,pressure has a significant influence on φ~2_(10),which decrease with rising pressure,while mass flow exerts but little influence.On the other hand,φ~2_(10) increases with rising steam quality,first quicker and then gradually slower.A formula for calculating the frictional pressure drop coefficient for single water phase flow is provided as well as an empirical correlation formula for calculating frictional pressure drop,in case of steam-water two phase flow.