Acceleration of Whole-body Patlak Parametric Image Reconstruction using Convolutional Neural Network

Tao Feng,Yizhang Zhao,Yun Dong,Shulin Yao
2019-01-01
Journal of Nuclear Medicine
Abstract:518 Introduction: Parametric imaging using the Patlak model has been shown to provide better quantification and improved specificity for cancer detection compared with SUV imaging. Current methods for generating parametric images include image-based analysis with reconstruction dynamic images (Indirect method) and direct parametric image reconstruction from listmode or sinogram data (Direct method). The direct method has been shown to provide much better image quality compared to the indirect method. However, it has also been shown that the convergence speed for the direct approach is much slower due to the inclusion of the Patlak model into the image reconstruction process. The direct approach also required either the listmode data or the dynamic sinograms, which usually takes a large amount of storage and may not be practical for large-scale analysis. Great potential has been demonstrated using the convolutional neural network (CNN) with deep learning for image processing. In this study, we train a CNN model to predict the images produced using the direct method from the images generated using the indirect approach. Faster reconstruction time and improved image quality can be expected without the need for the listmode or sinogram data.\nA total of 10 whole body FDG PET scans were collected using the whole-body dynamic scanning protocol, with 2 or 3 dynamic passes and 4 or 5 bed-positions scanned starting 40 minutes post-injection. Every bed position is 4-min long. The study has been approved by the Institutional Review Board of the hospital, and a written informed consent form has been obtained from each patient. The dynamic SUV images were reconstructed using 24 subsets with 2 iterations. Parametric images using the indirect method were acquired by matrix multiplication of the inverse of the Patlak model with the dynamic images. The direct parametric images were generated by combining the Patlak model into the system matrix. A total of 24 subsets and 60 iterations were used in the direct image reconstruction to ensure convergence. The population-based input function was used for both methods. The CNN with 6 layers were used for model training, the Patlak slope and intercept image generated from the indirect method were used as inputs and the slope image generated from the direct method was used as model output. 3D patches with the size of 56[asterisk]56[asterisk]56 were used for both inputs and outputs. A total of 4800 iterations with the batch size being 25 were used for model training. The leave-one-out cross-validation method was applied for the evaluation of the deep learning model. The normalized root mean square difference (RMSD) with the images generated using the direct approach was used for quantitative evaluation criteria.\nImages predicted using the CNN model (Indirect-CNN) showed much-reduced noise compared with the images generated using the indirect approach, and similar image quality was observed when compared with images generated using the direct approach. The time required for CNN prediction is negligible compared with direct image reconstruction. The average normalized RMSD for images generated using indirect-CNN was reduced to 15.5% from 34.5%, which was the normalized RMSD for images using the indirect method.\nThis study demonstrated the possibility to use CNN to replace the direct parametric image reconstruction process and provide similar parametric image quality using existing SUV images without the requirement of listmode or sinogram data.
What problem does this paper attempt to address?