Determination of reference temperature T-0 for A508-III forging using PCVN specimens based on Beremin toughness scaling model

Yupeng Cao,Hu Hui,Fu-Zhen Xuan,Yinbiao He,Hui Li
2012-01-01
Abstract:The aim of this paper is to use precracked Charpy-size specimen (PCVN) to measure Master Curve reference temperature T-0 for homemade A508-III forging. This study experimentally evaluates the use of PCVN specimens to estimated T-0 by comparing differences in T-0 results between PCVN and 0.5T-SE (B) specimen. It is found that the allowable limit of M-limit specified in ASTM E1921 is un-conservative. Even though T-0 value from PCVN satisfies the validity criterion in E1921, it is much lower than the 0.5T-SE(B) result. The fracture toughness data from PCVN specimens were scaled to the IT size by using Beremin toughness scaling model. Taking account of the constraint effect, the difference between T-0 values measured using PCVN specimens and 0.5T-SE (B) specimen is obviously reduced.
What problem does this paper attempt to address?