In Situ Experimental Measurement of Mercury by Combining PGNAA and Characteristic X-ray Fluorescence.

Yan Zhang,Zeen Yao,Bin Tang,Zhifeng Liu,Runlong Gong,Bisai Li,Zhuo Cheng,Bin Hu
DOI: https://doi.org/10.1016/j.apradiso.2020.109488
IF: 1.787
2021-01-01
Applied Radiation and Isotopes
Abstract:In our previous research, a new detection method was proposed to measure Hg and Pb simultaneously by combining Prompt Gamma-ray Neutron Activation Analysis (PGNAA) and X-ray Fluorescence (XRF) and proved by the Monte Carlo N-Particle (MCNP) simulation code. For further experimental verification, a combined measurement experimental facility, comprising an Am-241-Be neutron source, SAINT-GOBAIN Bismuth Germanate (BGO) as the.-ray detector, and an NaI detector with 25 mu m Be window as the X-ray detector, was presented. Specifically, the characteristic X-ray fluorescence of the Hg directly induced in this experimental facility was utilized to improve the limits of detection (LOD) of Hg instead of traditional excitation sources. The simulation and experiment results indicated that LOD for Hg by the combined measurement instrument was 19.4 mg kg(-1). The empirical formula of the calibration curve in this method was given based on the aforementioned calculations.
What problem does this paper attempt to address?