The Changes of Corneal Aspherical and Lacrimal Parameter after Phacoemulsitication

GAO Yun-xia,WU Xin-yi,LIU Fang-yi,WANG Qiang,ZHENG Kai-shen
DOI: https://doi.org/10.3760/cma.j.issn.1006-4443.2011.09.008
2011-01-01
Abstract:Objective To investigate the changes of corneal aspherical parameter and lacrimal film parameter after cataract phacoemulsification. Methods A total of 102 cases (146 eyes) underwent ultrasonic phacoemulsification were divided into 2 groups, group A (corneal incision) and group B (scleral incision). The subjective complains of dry eye, tear break-up time, corneal fluorescent staining and corneal map were measured preoperatively and 1 day, 1 week, 1 month and 3 months postoperatively. Results BUT time of 1 day (8.500±3.477s), 1 week (10.966±3.970s) and 1 month (13.418±3.898s) postoperatively were shorter than preoperative (15.0+4.318s); corneal fluorescent and dry eye syndromes changed significantly 1 week postoperatively, and went to normal after 3 months. The corneal Central Eccentricity Index (CEI) value changed apparently 1 month postoperatively (P<0.05);there was no statistical significance between group A and B, except 1 day posteratively. Pearson correlation between changes of CEI and BUT, no statistical significance was found. Conelusions In the early stage after phacoemulsification, corneal aspherical and lacrimal film parameter changes, no correlation is found between them.