Biomechanic results of poly(lactic-co-glycolic acid)/tricalcium phosphate scaffold with bone morphogenetic protein implanted in bone defects peri-porous-titanium in rabbit femur
Lei Peng,Shi-feng Song,Zhen Wang,Qi Chang,Zheng Sun,Yong Teng,Zhi Li,Guo-lin Meng,Yu-ming Cui
2009-01-01
Abstract:BACKGROUND:Histological changes in bone morphogenetic protein(BMP) and poly(lactic-co-glycolic acid)(PLGA)/tricalcium phosphate(TCP) artificial bone as furniture have been observed following implanting surrounding the porous titanium.However,the fixation characteristics of this material in the porous titanium are still unclear.OBJECTIVE:To evaluate the biomechanics characteristics of composite material of BMP and PLGA/TCP in repair of bone defects surrounding porous titanium.DESIGN,TIME AND SETTIN:The randomized,controlled,animal study was performed at the Animal Experimental Center,Fourth Military Medical University of Chinese PLA from February 2005 to September 2007.MATERIALS:Using negative pressure aspiration,bovine BMP suspension(5 mg) was compounded with PLGA/TCP at 5×103 Pa pressure.A total of 36 New Zealand rabbits were equally and randomly assigned into a control group and an experimental group.METHODS:A circular cylinder-shaped whole-wall defect(6 mm diameter,10 cm height) was made at 0.5 cm above femoral medial condyle.PLGA/TCP scaffold was filled surrounding the porous titanium in the hydroxyapatite layer in the control group.BMP and PLGA/ TCP composite were filled surrounding the porous titanium in the hydroxyapatite layer in the experimental group.MAIN OUTCOME MEASURES:Following 6,12,24 weeks of filling,biomechanics of the femur implanted with samples was measured,and samples following test were observed under a scanning electron microscope.RESULTS:Shear stress of all samples increased with the prolonged time.At 6 and 12 weeks,the shear stress was higher in the experimental group than in the control group(P < 0.05).Using the scanning electron microscope,at 6 weeks,the fracture face occurred on the surface implanted with bionic bone-bone,with a few bone tissue volumes on the mental surface.At 12 weeks,fracture face mainly occurred on the interface implanted with bionic bone-porous titanium or reconstituted woven bone or on the interface of woven bone-cortical bone.At 24 weeks,fracture face occurred on the interface of woven bone-cortical bone.CONCLUSION:BMP loaded with PLGA/TCP in repair of bone defects surrounding the porous titanium can better fix the bioprosthesis.