Diagnostic Value of BRAF V600E Mutation Combined with Shear Wave Elastography for Thyroid Nodule of Bethesda Ⅲ

Luo Jieli,Xu Kanlun,Huang Fengbo,Chen Jianshe,Sun Yang,Huang Pintong
DOI: https://doi.org/10.3760/cma.j.issn.1004-4477.2018.06.008
2018-01-01
Abstract:Objective To evaluate the diagnostic value of BRAF V600E mutation combined with shear wave elastography(SWE) for thyroid nodules of Bethesda Ⅲ diagnosed by fine-neddle aspiration(FNAC). Methods One hundred and seventeen thyroid nodules diagnosed as Bethesda Ⅲ in the department of ultrasound and confirmed by BRAF V600E gene detection, SWE examination and surgery were collected. BRAF V600E detection, SWE examination and both combined with pathological results were using to retrospective analysis. Results There were 75 benign nodules and 42 malignant nodules according to pathology. Sensitivity and negative predictive value of BRAF V600E combined with SWE were higher than single BRAF V600E mutation detection and SWE with statistically significant(P=0.01, 0.001; P=0.029, 0.01, respectively). There were no statistically differences between single BRAF V600E mutation detection and SWE for Bethesda Ⅲ nodules(P=0.483, 0.645). Conclusions BRAF V600E mutation detection combined with SWE can improve the sensitivity and negative predictive value in the diagnosis of Bethesda Ⅲ thyroid nodules. Key words: Shear wave elastography; Thyroid nodule; Bethesda Ⅲ category; BRAF V600E
What problem does this paper attempt to address?