Management of dislocated graft after Descemet's stripping with automated endothelial keratoplasty

Jing HONG,Yan-sheng HAO,Rong-mei PENG,Zhi-zhong MA
DOI: https://doi.org/10.3760/cma.j.issn.1006-4443.2010.02.006
2010-01-01
Abstract:Objective To survey the management of dislocaed graft after Descemet' s Stripping with Automated Endothelium Keratoplasty (DSAEK).To provide experience for DSAEK developing in china. Method Outcomes of 48 DSAEK cases were reviewed retrospoctively.10 patients had dislocation of donor graft after DSAEK.Among these, 2 patients were aphakic with integrity iris, while 8 patients were pseudophakic with iris defect.7 patients had history of glaucoma.The position of the graft was checked by slit-lamp microscopy and anterior segment optical coherence tomogmphy.The methods of reposition included bubble and viscoelastic, the procedure was that bubble or viscoelastic was injected to appose the graft further to the recipient sufface.Resttlts 10 patients were successfully repositioned.The rebubbling was applied in 2 aphakic cases and the viscoelastic was done in 8 cases who pseudophakic with iris defect.The intraocular pressure (IOP) was normal in 2 week post-reposition in all patients.3 patients occurred high LOP 3 week post-reposition.Conclusions The most complication is dislocation of graft in DSAEK.Rebubbling to reposition graft is a regular method in normal structure eyes, but viscoelastic reattaching the dislocated graft is effective way in abnormal structure eyes after DSAEK.
What problem does this paper attempt to address?