Posteromedial Tibial Plateau Split Fractures: a Biomechanical Study

曾智敏,罗从风,胡承方,曾炳芳
DOI: https://doi.org/10.3760/cma.j.issn.1671-7600.2010.03.013
2010-01-01
Abstract:Objective To compare 3 different fixation constructs used for the posteromedial tibial plateau split fractures in terms of biomechanical performance. Methods Twenty-four right synthetic tibiae were made into models of posteromedial tibial plateau split fractures before they were randomly assigned into 3 groups. Group A was instrumented with anteromedial limited contact-dynamic compress plate (LC-DCP),group B with lateral fixed-angle locking plate, and group C with posteromedial T-shaped plate. Vertical sub-sidence of the posteromedial fragment and the failure loads were measured under axial loads from 500 to 1500 N. Results In group C, the subsidence values under axial loads from 500 to 1500 N were 0.131±0.019 mm, 0. 437±0.064 mm and 0. 842±0. 117 mm respectively, and the load to failure was 3545±250 N. The posterior T-shaped buttress plate (group C) presented the best biomechanical performance(P<0.05)and group A the poorest (P<0.05). Conclusion The posterior-based buttress technique is biome-chanically the strongest fixation method for the posteromedial split tibial plateau fracture.