Application of biphasic positive airway pressure mechanical ventilation in neonatal respiratory failure

王礼周,庄德义,吴谨准,黄英,何必子
DOI: https://doi.org/10.3760/cma.j.issn.1673-4912.2008.06.014
2008-01-01
Abstract:Objective To evaluate the effect of biphasic positive airway pressure(BIPAP) mechanical ventilation on neonatal respiratory failure and compare it with conventional mechanical ventilation(CMV).Methods Fifty neonates with respiratory failures were randomly divided into BIPAP group (n=28) and CMV group (n=22).The dosage of Luminal was recorded and blood gas as well as mean airway pressure(MAP) were monitored at 0 h,6~12h、24~48h、48h after ventilation.Results 48 patients were discharged from the hospital,2 died of multiple organ failure.In BIPAP group,the total duration of mechanical ventilation was (70±35)h,which was significantly less than that (99±44)h in CMV group (P<0.05).The dosage of Luminal used during mechanical ventilation was significantly greater in CMV group than that in BIPAP group (P<0.05).MAP was significantly higher in CMV group than that in BIPAP group 24?h after ventilation (P<0.05).No significant difference in PaO2、PaCO2 and pH was found between the two modes.Conclusion BIPAP is an effective mode of mechanical ventilation therapy for neonatal respiratory failure and is operated easily and safely.