Electrochemical determination of butylhydroxyanisole (BHA) using a carbon fiber microelectrode modified by electrodeposition of gold nanoparticles and poly-NiTSPc film
Honorine Hortense Tchoumi Bougna,Evangeline Njanja,Serge Foukmeniok Mbokou,Raïssa Massah Tagueu,Yibor Fabrice Roland Bako,Maxime Pontié,Ignas Kenfack Tonle
DOI: https://doi.org/10.1007/s10800-024-02093-0
IF: 2.925
2024-03-03
Journal of Applied Electrochemistry
Abstract:We present an approach on the electrodeposition of gold nanoparticles (AuNPs) on a carbon fiber microelectrode (CFME) followed by deposition of nickel(II) tetrasulfonated phthalocyanine (p-NiTSPc) film by electropolymerization to form CFME-AuNPs/p-NiTSPc, for the sensitive determination of butylhydroxyanisole (BHA) using cyclic voltammetry (CV) and differential pulse voltammetry (DPV). Atomic force microscopy (AFM), scanning electron microscopy (SEM), and energy-dispersive X-ray spectroscopy (EDX) were used to characterize the topography, morphology, and elemental composition of CFME, CFME-AuNPs, CFME-p-NiTSPc, and CFME-AuNPs/p-NiTSPc, respectively. Additionally, the electrochemical impedance spectroscopy (EIS) technique was employed to evaluate the charge-transfer rate of the tested sensors. To establish the optimal conditions for the electroanalysis of BHA, various parameters were investigated, including the potential scan rate, pH, and electrolysis potential. CFME-AuNPs/p-NiTSPc demonstrated the highest BHA signal, corresponding to the highest active surface area of 0.025 cm 2 , compared to CFME-p-NiTSPc (0.024 cm 2 ), CFME-AuNPs (0.022 cm 2 ), and CFME (0.021 cm 2 ). In a phosphate buffer solution (PBS, 0.1 M; pH 3), a good linear relationship ( R 2 = 0.998) was observed between peak current intensities and BHA concentrations in the range of 10–80 μM, resulting to a detection limit (LOD) of 3.60 μM ( S / N = 3) and a quantification limit (LOQ) of 12 μM ( S / N = 10). The analytical HPLC technique was also tested for BHA determination within the concentration range of 5.55–55.48 μM and the obtained LOD was calculated to be 4.41 μM. The potential interference of certain species that could affect the BHA oxidation signal was also evaluated, followed by the application of CFME-AuNPs/p-NiTSPc in real water and Mitosyl ointment samples. The recovery values of BHA were acceptable, ranging from 96 to 99% and demonstrating that the developed sensor is highly sensitive and effective for detecting trace amounts of BHA.
electrochemistry